Plate-fin Refrigerated Air Dryer
Product Introduction
Product Features
| Model number | Gas processing capacity | Rated Power (kW) | Air interface | Microcomputer control | Drainage device | Dew point temperature display | Intake Air Temperature Display | Hot gas bypass | Rated Power supply voltage (V/Hz) |
| WZS-PD10S | 1.6 | 0.5 | RC1” | Optional equipment | Automatic drain valve | Optional equipment | Optional equipment | Optional equipment | 220/50 |
| WZS-PD20S | 2.6 | 0.66 | RC1” | Optional equipment | Optional equipment | Optional equipment | Optional equipment | 220/50 | |
| WZS-PD30S | 3.8 | 0.9 | RC1” | Optional equipment | Optional equipment | Optional equipment | Optional equipment | 220/50 | |
| WZS-PD50S | 6.5 | 1.3 | RC11/2” | Optional equipment | Optional equipment | Optional equipment | Optional equipment | 220/50 | |
| WZS-PD755 | 10.5 | 2.1 | RC2” | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 220/50 | |
| WZS-PD100S | 13.5 | 2.3 | RC2” | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 220/50 | |
| WZS-PD120S | 17 | 2.8 | RC11/2” | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 220/50 | |
| WZS-PD150S | 21.5 | 3 | DN80 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD1805 | 25 | 3.2 | DN80 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD200 | 28.5 | 3.5 | DN80 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD250S | 32 | 4 | DN80 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD300S | 37 | 4.5 | DN100 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD400S | 45 | 5.8 | DN100 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD5005 | 55 | 6.5 | DN250 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 | |
| WZS-PD600S | 65 | 7.5 | DN250 | Standard configuration | Standard configuration | Standard configuration | Standard configuration | 380/50 |
Rated inlet pressure: 0.7 MPa (operating within the range of 0.6 MPa to 1.0 MPa; other operating pressures available upon request)
Rated inlet air temperature: 50°C (maximum inlet air temperature < 80°C)
Pressure dew point: 2–10°C
Rated ambient temperature: 32°C (operable within the range of 2°C to 45°C)
Pressure loss: <0.02 MPa
Cooling method: Air-cooled
Refrigerant: R22 (environmentally friendly refrigerants such as R407 and R134a are available upon request)
Installation method: Indoor installation on a concrete floor without a foundation, with a clearance of at least 1.5 meters around the perimeter.
| Model number | Gas processing capacity | Rated Power supply voltage (V/Hz) | Rated Power (kW) | Air inlet and outlet | Equipment weight (kg) | External dimensions (mm) |
| WZW-D10AH | 1.5 | 220/50 | 0.8 | G1” | 52 | 710x440x680 |
| WZW-D20AH | 2.5 | 220/50 | 0.9 | G1” | 73 | 800x440x880 |
| WZW-D30AH | 3.8 | 220/50 | 1.1 | G11/2” | 95 | 930x500x980 |
| WZW-D50AH | 6.5 | 220/50 | 1.5 | G11/2” | 115 | 1000x600x1030 |
| WZW-D75AH | 10.5 | 220/50 | 2.2 | G2” | 160 | 1150x650x1250 |
| WZW-D100AH | 13.5 | 380/50 | 2.8 | G21/2” | 225 | 1300x650x1350 |
| WZW-D120AH | 17 | 380/50 | 2.8 | G21/2” | 235 | 1300x650x1350 |
| WZW-D150AH | 21.5 | 380/50 | 5.2 | G3” | 345 | 1430x700×1450 |
| WZW-D180AH | 25 | 380/50 | 5.2 | G3” | 395 | 1430x700x1450 |
| WZW-D200AH | 28.5 | 380/50 | 5.5 | DN80 | 530 | 1600x1550x850 |
| WZW-D250AH | 32 | 380/50 | 6.2 | DN100 | 580 | 1600x1550x850 |
| WZW-D300AH | 37 | 380/50 | 7.8 | DN100 | 680 | 1730x1700x850 |
| WZW-D350AH | 41.5 | 380/50 | 7.8 | DN100 | 750 | 1730x1700x850 |
| WZW-D400AH | 45 | 380/50 | 10.5 | DN100 | 800 | 1880x1900x950 |
| WZW-D450AH | 50 | 380/50 | 10.5 | DN125 | 850 | 1880x1900x950 |
| WZW-D500AH | 55 | 380/50 | 11.8 | DN125 | 910 | 1800×1950x1300 |
| WZW-D550AH | 60 | 380/50 | 11.8 | DN125 | 950 | 1800x1950x1300 |
| WZW-D600AH | 65 | 380/50 | 11.8 | DN125 | 1100 | 1850x2300x1330 |
| WZW-D650AH | 70 | 380/50 | 11.8 | DN125 | 1140 | 1850x2300x1330 |
| WZW-D700AH | 75 | 380/50 | 13.9 | DN125 | 1280 | 1860x2400×1400 |
| WZW-D750AH | 80 | 380/50 | 13.9 | DN125 | 1350 | 1860x2400×1400 |
| WZW-D800AH | 85 | 380/50 | 15.9 | DN150 | 1450 | 1900×2400×1420 |
| WZW-D900AH | 95 | 380/50 | 16.7 | DN150 | 1600 | 1900x2450x1400 |
| WZW-D1100AH | 110 | 380/50 | 18.3 | DN150 | 1700 | 1980x2450×1500 |
| WZW-D1200AH | 120 | 380/50 | 20.6 | DN150 | 1800 | 1980x2450x1500 |
| WZW-D1400AH | 140 | 380/50 | 21.8 | DN200 | 1950 | 2050x2700×1550 |
| WZW-D1600AH | 160 | 380/50 | 26 | DN200 | 2100 | 2123x2650x1550 |
D‑series refrigerated compressed air dryers are classified into two types based on the cooling method of the refrigeration system: air‑cooled and water‑cooled. When selecting a D‑series refrigerated dryer, it is necessary to specify the maximum flow rate of the compressed air to be treated (Nm³/min), the maximum and minimum inlet pressures (MPa), the maximum inlet temperature (°C), the nominal pressure dew point (°C), and the maximum ambient temperature (°C). Using these parameters, consult the table below to determine the selection factor, then calculate the actual nominal treatment flow rate.
Keywords:
Customer visit
Packaging and shipping
More products
-
Oil-injected Rotary Screw Air Compressor
-
Single-stage Permanent Magnet Variable Speed Drive Rotary Screw Air Compressor
-
Low Pressure Permanent Magnet Variable Speed Drive Rotary Screw Air Compressor
-
Medium & High Pressure Permanent Magnet Variable Speed Drive Rotary Screw Air Compressor
-
Special Rotary Screw Air Compressor for Laser Cutting & Other Applications
Oil-injected Rotary Screw Air Compressor
-
Air Treatment Equipment
Get a quote
Please provide us with more details so we can connect you with the appropriate representative.