Plate-fin Refrigerated Air Dryer

Gas handling capacity: 1.6–160 m³/min Rated Power: 0.5–26 kW Model numbers: WZS-PD10–600S, WZW-D10–1600AH Applications: Compatible with screw air compressors of corresponding displacement.

Product Introduction

Plate-fin Refrigerated Air Dryer
+
  • Plate-fin Refrigerated Air Dryer

Product Features

Model numberGas processing capacityRated Power (kW)Air interfaceMicrocomputer controlDrainage deviceDew point temperature displayIntake Air Temperature DisplayHot gas bypassRated Power supply voltage (V/Hz)
WZS-PD10S1.60.5RC1”Optional equipmentAutomatic drain valveOptional equipmentOptional equipmentOptional equipment220/50
WZS-PD20S2.60.66RC1”Optional equipmentOptional equipmentOptional equipmentOptional equipment220/50
WZS-PD30S3.80.9RC1”Optional equipmentOptional equipmentOptional equipmentOptional equipment220/50
WZS-PD50S6.51.3RC11/2”Optional equipmentOptional equipmentOptional equipmentOptional equipment220/50
WZS-PD75510.52.1RC2”Standard configurationStandard configurationStandard configurationStandard configuration220/50
WZS-PD100S13.52.3RC2”Standard configurationStandard configurationStandard configurationStandard configuration220/50
WZS-PD120S172.8RC11/2”Standard configurationStandard configurationStandard configurationStandard configuration220/50
WZS-PD150S21.53DN80Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD1805253.2DN80Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD20028.53.5DN80Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD250S324DN80Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD300S374.5DN100Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD400S455.8DN100Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD5005556.5DN250Standard configurationStandard configurationStandard configurationStandard configuration380/50
WZS-PD600S657.5DN250Standard configurationStandard configurationStandard configurationStandard configuration380/50

Rated inlet pressure: 0.7 MPa (operating within the range of 0.6 MPa to 1.0 MPa; other operating pressures available upon request)

Rated inlet air temperature: 50°C (maximum inlet air temperature < 80°C)

Pressure dew point: 2–10°C

Rated ambient temperature: 32°C (operable within the range of 2°C to 45°C)

Pressure loss: <0.02 MPa

Cooling method: Air-cooled

Refrigerant: R22 (environmentally friendly refrigerants such as R407 and R134a are available upon request)

Installation method: Indoor installation on a concrete floor without a foundation, with a clearance of at least 1.5 meters around the perimeter.

Model numberGas processing capacityRated Power supply voltage (V/Hz)Rated Power (kW)Air inlet and outletEquipment weight (kg)External dimensions (mm)
WZW-D10AH1.5220/500.8G1”52710x440x680
WZW-D20AH2.5220/500.9G1”73800x440x880
WZW-D30AH3.8220/501.1G11/2”95930x500x980
WZW-D50AH6.5220/501.5G11/2”1151000x600x1030
WZW-D75AH10.5220/502.2G2”1601150x650x1250
WZW-D100AH13.5380/502.8G21/2”2251300x650x1350
WZW-D120AH17380/502.8G21/2”2351300x650x1350
WZW-D150AH21.5380/505.2G3”3451430x700×1450
WZW-D180AH25380/505.2G3”3951430x700x1450
WZW-D200AH28.5380/505.5DN805301600x1550x850
WZW-D250AH32380/506.2DN1005801600x1550x850
WZW-D300AH37380/507.8DN1006801730x1700x850
WZW-D350AH41.5380/507.8DN1007501730x1700x850
WZW-D400AH45380/5010.5DN1008001880x1900x950
WZW-D450AH50380/5010.5DN1258501880x1900x950
WZW-D500AH55380/5011.8DN1259101800×1950x1300
WZW-D550AH60380/5011.8DN1259501800x1950x1300
WZW-D600AH65380/5011.8DN12511001850x2300x1330
WZW-D650AH70380/5011.8DN12511401850x2300x1330
WZW-D700AH75380/5013.9DN12512801860x2400×1400
WZW-D750AH80380/5013.9DN12513501860x2400×1400
WZW-D800AH85380/5015.9DN15014501900×2400×1420
WZW-D900AH95380/5016.7DN15016001900x2450x1400
WZW-D1100AH110380/5018.3DN15017001980x2450×1500
WZW-D1200AH120380/5020.6DN15018001980x2450x1500
WZW-D1400AH140380/5021.8DN20019502050x2700×1550
WZW-D1600AH160380/5026DN20021002123x2650x1550

D‑series refrigerated compressed air dryers are classified into two types based on the cooling method of the refrigeration system: air‑cooled and water‑cooled. When selecting a D‑series refrigerated dryer, it is necessary to specify the maximum flow rate of the compressed air to be treated (Nm³/min), the maximum and minimum inlet pressures (MPa), the maximum inlet temperature (°C), the nominal pressure dew point (°C), and the maximum ambient temperature (°C). Using these parameters, consult the table below to determine the selection factor, then calculate the actual nominal treatment flow rate.

Previous:

Next:

Customer visit

Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Brazilian customer visit
Visit by foreign clients
Visit by foreign clients

Packaging and shipping

Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping

More products

Get a quote

Please provide us with more details so we can connect you with the appropriate representative.

Submit message
%{tishi_zhanwei}%