Waste Heat Recovery Unit (Conventional Circulation Type)

A fully welded plate heat exchanger made of stainless steel 316L, specifically designed for waste heat recovery in air compressors.

Product Introduction

Waste Heat Recovery Unit (Conventional Circulation Type)
+
  • Waste Heat Recovery Unit (Conventional Circulation Type)

Product Features

High-efficiency, reliable heat exchangers:

A fully welded plate heat exchanger made of stainless steel 316L, specifically designed for waste heat recovery in air compressors.

The heat exchanger is designed with a small temperature difference and low pressure drop, employing an equal-flow, full-counterflow heat exchange configuration. Upon entering the unit, the working fluids are evenly distributed across all flow channels, ensuring uniform heat transfer, minimizing system pressure loss, and reducing fouling through enhanced turbulence, thereby improving heat transfer efficiency.

Its features include: high heat-transfer efficiency, low pressure drop, minimal liquid holdup, long service life, and the ability to operate continuously under high-temperature (200°C) and high-pressure (4.5 MPa) conditions.

Intelligent Control Mode:

Our company has independently developed a fully intelligent microcomputer monitoring system that operates entirely on preset parameters, providing round-the-clock unattended operation.

The color display dynamically shows the system’s operating status, while text messages clearly and accurately convey fault information, making it easy to understand at a glance.

Displays the air compressor oil temperature, hot water temperature, and water tank level; indicates the operating status of the make-up water system, the circulating water system, and the water supply system.

Low‑temperature and high‑temperature protection for the air compressor oil, over‑temperature protection for the coolant, low‑water level protection for the water tank, dry‑run protection for the water pump, pump overload protection, freeze‑protection, and equipment fault alarm.

It features a power‑failure recovery auto‑start function and operates automatically in response to the air compressor’s start and stop commands.

485 output port, enabling multi-unit coordinated control, remote monitoring of equipment operating status, and remote system operation. Advanced regulation technology:

All sensors and valves have undergone tens of thousands of rigorous reliability and safety tests, ensuring their dependable performance and durability.

Precise signal acquisition ensures the safe operation of the air compressor while achieving excellent energy-saving performance. Electrical components:

All components are sourced from reputable brands, ensuring system stability and durability.

Single-oil-circuit recovery-type model

Product model Compatible air compressor (kW/HP) Waste heat recovery capacity (kW) Outlet water temperature Water production rate m³/h (temperature rise of 40°C) Interface pipe diameter (oil circuit/water circuit) External dimensions mm (L×W×H)
WZS-20A/DY15kW/20HP12 55~80℃ 0.26DN25/DN32 700×400x800
WZS-30A/DY22kW/30HP17.6 55~80℃ 0.38DN25/DN32 700×400×800
WZS-40A/DY30kW/40HP24 55~80℃ 0.52DN25/DN32 700×400×800
WZS-50A/DY37kW/50HP29.6 55~80℃ 0.64DN25/DN32 700×400×800
WZS-60A/DY45kW/60HP36 55~80℃ 0.78DN25/DN32 750×400×870
WZS-75A/DY55kW/75HP44 55~80℃ 0.95DN25/DN32 750×400×870
WZS-100A/DY75kW/100HP60 55~80℃ 1.3DN50/DN50 750×400×870
WZS-125A/DY90kW/125HP72 55~80℃ 1.6DN50/DN50 850×460×905
WZS-150A/DY110kW/150HP88 55~80℃ 1.9DN50/DN50 850×460×905
WZS-175A/DY132kW/175HP105.6 55~80℃ 2.3DN50/DN50 850×460×905
WZS-200A/DY150kW/200HP120 55~80℃ 2.6DN50/DN50 850×460×905
WZS-220A/DY160kW/220HP128 55~80℃ 2.8DN50/DN50 850×460×905
WZS-250A/DY185kW/250HP148 55~80℃ 3.2DN50/DN50 900×500×1000
WZS-300A/DY225kW/300HP180 55~80℃ 3.8DN50/DN50 900×500×1000
WZS-350A/DY250kW/350HP200 55~80℃ 4.3DN50/DN50 900×500×1000
WZS-400A/DY300kW/400HP240 55~80℃ 5.1DN50/DN50 1100×600×1100
WZS-450A/DY315kW/450HP252 55~80℃ 5.4DN50/DN50 1100×600×1100
WZS-500A/DY355kW/500HP284 55~80℃ 6.1DN50/DN50 1200×650×1200
WZS-550A/DY400kW/550HP320 55~80℃ 6.8DN65/DN65 1200×650×1200
WZS-600A/DY450kW/600HP360 55~80℃ 7.7DN65/DN65 1200×650×1200

Dual‑oil‑circuit recovery configuration (one unit matched to two air compressors)

Product model Compatible air compressor (kW/HP) Waste heat recovery capacity (kW) Outlet water temperature Water production rate m³/h (temperature rise of 40°C) Interface pipe diameter (oil circuit/water circuit) External dimensions mm (L×W×H)
WZS-30A/SY22kW/30HP35.2 55~80℃ 0.76DN25/DN32 750×400×870
WZS-50A/SY37kW/50HP59.2 55~80℃ 1.3DN25/DN32 750×400×870
WZS-75A/SY55kW/75HP88 55~80℃ 1.9DN25/DN32 850×460×905
WZS-100A/SY75kW/100HP120 55~80℃ 2.6DN50/DN50 900×500×1000
WZS-125A/SY90kW/125HP144 55~80℃ 3.1DN50/DN50 900×500×1000
WZS-150A/SY110kW/150HP176 55~80℃ 3.8DN50/DN50 900×500×1000
WZS-175A/SY132kW/175HP211.2 55~80℃ 4.5DN50/DN50 900×500×1000
WZS-200A/SY150kW/200HP240 55~80℃ 5.1DN50/DN50 1100×600×1100
WZS-220A/SY160kW/220HP256 55~80℃ 5.5DN50/DN50 1100×600×1100
WZS-250A/SY185kW/250HP296 55~80℃ 6.3DN50/DN50 1200×650x1200
WZS-300A/SY225kW/300HP360 55~80℃ 7.7DN50/DN50 1200×650×1200

Oil and gas dual‑path recovery system model

Product model Compatible air compressor (kW/HP) Waste heat recovery capacity (kW) Outlet water temperature Water production rate m³/h (temperature rise of 40°C) Interface pipe diameter (oil circuit/water circuit) External dimensions mm (L×W×H)
WZS-100A/YQ75kW/100HP66 55~80℃ 1.5

DN50/DN50/DN50

900×500×1000
WZS-125A/YQ90kW/125HP79.2 55~80℃ 1.7

DN50/DN65/DN50

900×500×1000
WZS-150A/YQ110kW/150HP96.8 55~80℃ 2.1

DN50/DN65/DN50

900×500×1000
WZS-175A/YQ132kW/175HP116 55~80℃ 2.5

DN50/DN80/DN50

900×500×1000
WZS-220A/YQ160kW/220HP140.8 55~80℃ 3.1

DN50/DN80/DN50

1100×600×1100
WZS-250A/YQ185kW/250HP162.8 55~80℃ 3.5

DN50/DN100/DN50

1200×650×1200
WZS-300A/YQ225kW/300HP198 55~80℃ 4.3

DN50/DN100/DN50

1200x650x1200
WZS-350A/YQ250kW/350HP220 55~80℃ 4.7

DN50/DN100/DN50

1200×650x1200

Note: The above specifications are based on the air compressor operating at full load with a water temperature rise of 40°C. Should product modifications result in changes to the specifications, the data listed on the nameplate shall prevail.

Keywords:

Customer visit

Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Customer visit
Brazilian customer visit
Visit by foreign clients
Visit by foreign clients

Packaging and shipping

Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping
Packaging and shipping

More products

Get a quote

Please provide us with more details so we can connect you with the appropriate representative.

Submit message
%{tishi_zhanwei}%